EP203 GroupEP203 Automatic Extinguisher Panel

The EP203 three zone automatic extinguisher panel has been specifically designed for use in areas housing expensive, dangerous or irreplaceable items of equipment.

Third-party approved by the LPCB to EN 12094-1 (the European standard for Fixed Firefighting Systems – Components for Gas Extinguishing Systems) and EN54 parts 2 and 4, the panel epitomises quality, durability and reliability.

Featuring an intuitive 128 x 64 pixel two-colour graphic display that gives clear and concise feedback to the user, installer and commissioning engineer, the panel also includes six monitored inputs (including hold and abort), a time stamped log, adjustable flood times and volt-free changeover relays for fire, local fire, 1st stage active, 2nd stage active, extractor fan and fault.

The panel is supplied in an elegantly styled, durable enclosure with all of its electronics – apart from its powerful 3A EN54-4 switch mode PSU – mounted on a detachable metal bridge plate for ease of installation. A wide range of ancillaries are also available including remote status units, hold-off and abort buttons, line terminators and output expansion relay boards.

An overview of the EP203’s inputs and outputs

EP203 Schematic

Key features

  • Third-party LPCB certificated to EN 12094 part 1 and EN54 parts 2 and 4
  • Functions as a standard three zone fire panel with additional circuitry for controlling the release of 
    fire-suppressing gas into protected areas
  • Unique 128 x 64 pixel graphical display facilitates straightforward system programming
  • Any combination of activated zones can be programmed to automatically start the panel’s extinguishant release sequence
  • Includes a pull-down front-panel manual release button and two keyswitches for accessing the panel’s functions and toggling between auto/manual mode
  • Three conventional sounder circuits (two x 1st stage, one x 2nd stage)
  • Powerful 3A EN54-4 compliant switch mode PSU
  • Low quiescent current – less than 40mA on mains fail
  • Wide range of monitored inputs and auxiliary outputs (see schematic)
  • Abort and hold inputs allow the panel’s release sequence to be cancelled or suspended at any time
  • Time-stamped event log
  • RS485 connections for up to eight flush or surface remote status units with their own LCDs, manual release and mode (auto/manual) switches. Single gang economy status units (without an LCD) are also available.
  • Extensive range of commissioning and engineering functions
  • Optional relay expansion boards and single gang abort and hold buttons
  • Ideal for use in computer rooms, telecommunication centres, archive storage areas, chemical plants, generator rooms, museums, etc..
  • System line terminator included with all panels

EP203 reference sites

Buildings protected by C-TEC’s EP203 Automatic Extinguisher panel include (click picture for details):

Waterways Ireland Coop HQ Synergy House
Waterways Ireland Eniskillen, Ireland United Co-Op HQ
Rochdale, Lancs
Synergy House
Manchester

Literature & Instructions

PDF
PDF
PDF
PDF
 

Additional EP203 range instructions can be downloaded from our Downloads section

Cease Fire Italia

i213 STOCK ITEM

 

Cease Fire Italia

 

GN-206

Product name:GN-206

View:1138 degree

*Finest alumina,innovative plastic cover,esthetic

*Super bright LED luminaire

*Size:380*160*23MM

*Ni-cd battery 1.2V800mAh

*Emergnecy time:>90mins

Packing:

20PCS/41X32.5X36.5CM/CTN

11920PCS/20’CY

Cease Fire Italia

 

GCB-200

GX200SR RED COMBO LIGHT

HOUSING

Injection-molded thermoplastic ABS housing.

UL 94V-0 flame rating.

Use small square head.

Innovative, snap-together design allows for fast installation.

Replaceable directional chevron inserts are easily

removed and reinserted.

Letters 6″ height with 3/4″ stroke.

Single or double face configuration.

Suitable for damp location.

MOUNTING

Wall or Ceiling mounting.

Housing snaps to canopy with simple twist and locking tightly secure housing to canopy.

ELECTRICAL

120/277VAC Dual voltage operation.

LED indicator light and push button test switch.

Remote capability,may power additional remote heads (up to 15W) with additional battery.

1 battery with 3.5W remote capability.

LAMPS

LEDs mounted on print circuit board. (for Exit Sign)

LED lamps are operating in normal (AC input) and emergency (DC input)  modes.

Φ3mm LED lamp for emergency mode

BATTERY

Lead-Acid Battery (6V 4.5Ah)

May use additional battery, when add remote light heads to the fixture. (Total 2pcs x 6V 4.5Ah battery)

Low voltage battery disconnection.

PACKING

2pcs/35.5x29x40.6cm/8.6kgs/CTN

1388pcs/20’FT

COLOR

GCB-200SR(Red)

GCB-200SG(Green)

Cease Fire Italia

Exit (UL)

GSEL-200

HOUSING

Compact and decorative design.

Aluminum housing with high grade acrylic panel.

Replaceable acrylic EXIT panel.

Removable directional indicators.

Removable front cover for easy installation and battery maintenance.

Letters 6″ height with 3/4″ stroke.

Suitable for damp location.

MOUNTING

Wall or Ceiling mounting, sloped ceiling or high ceiling with tilt angle.

Housing snaps to canopy with simple twist and locking tightly secure housing to canopy.

ELECTRICAL

120/277VAC Dual voltage operation.

Test switch and charge rate indicator.

LAMPS

Low consumption red or green LED lamp.

LED lamps are operating in normal (AC input)  and emergency (DC input)  modes.

BATTERY

Nickel-cadmium battery deliver more than 90 minutes capacity to emergency lamps.

24 hours recharge after 90 minutes discharge.

Low voltage battery disconnection-Preventing deep discharge damage to the battery.

PACKING

6PCS/44X34X24CM/13.8kgs/CTN

4842pcs/20’FT

COLOR

GSEL-200SR(Single Face Red)

GSEL-200SG(Single Face Green)

GSEL-200DR(Double Faces Red)

GSEL-200DR(Double Faces Green)

Cease Fire Italia

GX-200N

HOUSING

Injection-molded thermoplastic ABS housing.

UL 94V-0 flame rating.

Innovative, snap-together design allows for fast installation.

Replaceable directional chevron inserts are easily removed and reinserted.

Letters 6″ height with 3/4″ stroke.

Single or double face configuration.

Suitable for damp location.

MOUNTING

Universal (Wall, Side or Ceiling) mounting.

Housing snaps to canopy with simple twist and locking

tightly secure housing to canopy.

ELECTRICAL

120/277VAC Dual voltage operation.

Low energy consumption-only 2.0 watts at 120V.

LED indicator light and push button test switch

 

LAMPS

LEDs mounted on print circuit board.

LED lamps are operating in normal (AC input) and emergency (DC input) modes.

 

BATTERY

Nickel-Cadmium battery.

24 hours recharge after 90 minutes discharge.

PACKING

12pcs/38.7x32x40cm/16.5kgs/CTN

7140pcs/20FT

COLOR

GX-200NR(Red)

GX-200NG(Green)

Cease Fire Italia

 

GXL-150

HOUSING

Injection-molded thermoplastic ABS housing.

UL 94V-0 flame rating.

Innovative, snap-together design allows for fast and easy installation.

Two fully adjustable glare-free round shape light heads for emergency light.

 

MOUNTING

Wall or Ceiling mounting.

Easily removed mounting knock-outs and J-box pattern on back panel

ELECTRICAL

120/277VAC Dual voltage operation.

Test switch and charge rate indicator.

 

LAMPS

2X6V 5W wedge base T15 DC lamps for emergency mode.

 

BATTERY

Lead – Acid Battery (6V 4.5Ah) delivers more than 90 minutes capacity to emergency lamps.

24 hours recharge after 90 minutes discharge.

Low voltage battery disconnection-Preventing deep

discharge damage to the battery.

PACKING

6pcs/33.4×32.7x31cm/12.5kgs/CTN

5136pcs/20’FT

LOGOFOH04

FOH04

FBI PIV-certified single finger
Live Scanner for identification

Brochure Download

User Manual Download 

Wide Input Area

0.8” fingerprint sensing area

FOH04
FOH04

FBI-PIV Certified Scanner

Advanced optical system for getting high quality fingerprint images

Superior Algorithm

Fast and accurate algorithm for reading fingerprints

FOH04

Specification

Detail Specification FOH04

Optical Resolution 500dpi (400 X 400 pixels), 256 gray level Speed 15 frames per second(fps)
Size of Fingerprint Input Area 21 X 21 mm Supply Voltage DC 5V +/- 10% supplied by USB
Size of Fingerprint Image 42 X 42 mm Operating System Windows 2000, XP and 7
Dimension 74 X 92 X 84 mm Certificates FBI, KC, CE, FCC, RoHS
Optical Resolution 500dpi (400 X 400 pixels), 256 gray level
Size of Fingerprint Input Area 21 X 21 mm
Size of Fingerprint Image 42 X 42 mm
Speed 15 frames per second(fps)
Supply Voltage DC 5V +/- 10% supplied by USB
Operating System Windows 2000, XP and 7
Dimension 74 X 92 X 84 mm
Certificates FBI, KC, CE, FCC, RoHS

 

LOGOFOH02

FOH02

USB Fingerprint Reader which is
also available in optional
RFID reader or Mifare reader

Brochure Download

User Manual Download 

USB Connection

Able to connect to Microsoft Windows OS
(Plug and Play)
FOH02
FOH02
FOH02

Access Control Software

Compatible with access control management software UNIS

Superior Algorithm

Fast and accurate algorithm for reading fingerprints
FOH02

Specification

Detail Specification FOH02

Optical Resolution 500dpi Speed 15 frames per second(fps)
Supported Card – 125KHz proximity card (FOH02RF)– 13.56MHz smart card (FOH02SC) Operating System Windows 2000, XP, 2003, Vista and 7
Dimension  74 X 84 X 95 mm Certificates CE,

LOGO

Bioseal-P

Bio Seal-P

Multi-purpose Fingerprint Data Printer

Website Login Credentials

Up to 10 login data such as passwords can be
saved with each fingerprint
Limits fingerprint authentication attempts.
Bioseal-P
Bioseal-P

Frequently Asked User Info

Address, phone number, credit card number, etc.
User registration process can be expedited.

Strengthened Industrial Security

More secure way of accessing customer
accounts in financial industry through
fingerprint authentication.
Bioseal-P

Specification

Detail Specification BioSeal-P

CPU 32Bit RISC CPU 192MHz Current Consumption Stand by : 30+/-5mA (Fingerprint OFF) Active : 220+/-10mA (Fingerprint ON)
Operating Voltage USB DC 5V
Operating System Windows XP, Vista and 7 Dimension 31 X 70 X 38 mm
CPU 32Bit RISC CPU 192MHz
Operating Voltage USB DC 5V
Operating System Windows XP, Vista and 7
Current Consumption Stand by : 30+/-5mA (Fingerprint OFF) Active : 220+/-10mA (Fingerprint ON)
Dimension 31 X 70 X 38 mm

Configuration

See what’s included in the BioSeal-P

Bioseal-P

LOGOVS-R20D

VS-R20D

Dummy Card Reader

Brochure Download

User Manual Download 

Dummy Card Reader

Compatible with MCP-040 controller

VS-R20D
VS-R20D

Dustproof / Waterproof

IP65 level of Dustproof / Waterproof structure

Status Indicator

3-color high luminance LED

VS-R20D

Specification

Detail Specification VS-R20D

Type RFID Communication Wiegand Out, RS485
Supported Cards EM, Mifare, DESFire Dimension 70 X 124 X 11 mm

 

Type RFID
Communication Wiegand Out, RS485
Supported Cards EM, Mifare, DESFire
Dimension 70 X 124 X 11 mm

Configuration

See what’s included in the VS-R20D

VS-R20D

LOGO

MCP-040

MCP-040

4 Door controller

THE MCP-040 is a 4 Door Controller with an integrated 8 zone Intruder Alarm System.
MCP-040

4 Lock Outputs

Control 4 doors

MCP-040

Remote Setting

TCP/IP Communication to UNIS Server and Web server

MCP-040

Monitoring

Supervised Bell Output

MCP-040

Backup Battery

DC 12V, 7A (Optional)

Specification

Detail Specification MCP-040

CPU 32bits RISC processor(ARM Cortex-M3 Core) Memory 8MB serial flash
Schedules 1,024 Max Users 50,000
Event Log 51,200 Lock Interface – EM, strike, auto door
– 2 Locks, 2 relays or 2 locks, 4 relays (Optional)
– 2 Door status, 2 lock status
– 2 Exit input port
Communication RS485 2port, Wiegand 4port(4xIN), RS232 1port(Debug)

Configuration

See what’s included in the MCP-040

MCP-040

LOGOSR-100FP

SF-100FP

The SR100FP is a slave reader which can be paired with either an
AC2100 or AC2100H biometric terminal.

Slave Reader

Compatible with AC-2100(H)

SR-100FP
SR-100FP

Anti-passback

Makes provision for local Anti-passback

Specification

Detail Specification SF-100FP

Type  Biometric Communication  RS485
Supported Cards EM, Mifare, DESFire  Dimension  55.5 X 111 X 40.5 mm

 

Type Biometric
Communication RS485
Supported Cards EM, Mifare, DESFire
Dimension 55.5 X 111 X 40.5 mm

Configuration

See what’s included in the SF-100FP

SR-100FP

LOGO

FMD-10

FMD-10

The FMD10 is a budget Biometric Terminal complete with
13.56MHz card reader. The terminal is utilised in stand-alone
environments or in conjunction with the MCP-040 where
biometric access control is required but networking and
cabling is problematic

Brochure Download

User Manual Download 

Bluetooth-enabled Terminal

Bluetooth communication to mobile device
FMD-10
FMD-10
FMD-10

Smartphone Application
(UNIS-B plus, imkey)

Access control & mobile key application by Android, iOS

Specification

Detail Specification FMD-10

Supply Voltage DC 12V or 24V Max Users 1,000
Communication Bluetooth, Wiegand Out, RS485  Log Capacity  10,000
Relay / Buzzer 1 Relay / 1 Buzzer Dimension 72 x

LOGO

 

AC-1000

AC-1000

VIRDI RF/Smart card authentication system is widely applicable
to various business solutions through TCP/IP networked
application software. We guarantee the advantage of high
reliability and cost effectiveness

Card and Key Tag

AC-1000
AC-1000

Authentication

Supports complex authentication using RF card, and/or ID/Password for greater safety.
AC-1000

Specification

Detail Specification AC-1000

CPU RISC 32bit CPU Memory 4MB Flash + 8MB SD RAM
LCD 128×64 Graphic Display LCD Max Users 15,000
Communication TCP/IP, Wiegand In/Out, RS485, RS232 Log Capacity 17,000
Dimension 140 X 89 X 28 mm Certificates KC, CE, FCC, RoHS

 

CPU RISC 32bit CPU
Memory 4MB Flash + 8MB SD RAM
LCD 128×64 Graphic Display LCD
Max Users 15,000
Communication TCP/IP, Wiegand In/Out, RS485, RS232
Log Capacity 17,000
Dimension 140 X 89 X 28 mm
Certificates KC, CE, FCC, RoHS

Configuration

See what’s included in the AC-1000

AC-1000

 

LOGOAC-2100

AC-2100

Fingerprint Authentication Device
Upgraded new-generation technology,
convenience, and design with LCD, LED, and
adjacent sensor technology.

Dustproof / Waterproof

IP65 level of Dustproof / Waterproof structure
IPX3 rating the international waterproofing standard!
It can be installed in virtually any location.
AC-2100
AC-2100

Local Anti-passback

Supporting anti-passback function
with a slave reader(SR-100FP)

USB Memory

Download users and transaction logs
using a USB Memory Stick
AC-2100
AC-2100

Specification

Detail Specification AC-2100

CPU RISC 266MHz, 32bit CPU Memory 4MB Flash + 8MB SD RAM
LCD 128×64 Graphic Display LCD Max Users 100 / 1,500
Communication TCP/IP, Wiegand In/Out,
RS485, RS232, Wi-Fi(Optional)
Log Capacity 5,000
Dimension 93 X 170 X 40 mm Certificates CE, FCC, RoHS
CPU RISC 266MHz, 32bit CPU
Memory 4MB Flash + 8MB SD RAM
LCD 128×64 Graphic Display LCD
Max Users 100 / 1,500
Communication TCP/IP, Wiegand In/Out, RS485, RS232, Wi-Fi(Optional)
Log Capacity 5,000
Dimension 93 X 170 X 40 mm
Certificates CE, FCC, RoHS

Configuration

See what’s included in the AC-2100

AC-2100

 

LOGO

 

AC-6000

AC-6000

High-End Fingerprint Terminal

This state of the art terminal embraces the latest technology
with a large color touch screen LCD,
embedded digital camera and extremely fast processor.

1.3 Mega Pixel Digital Camera

Records a digital image of each user
at the time of the transaction
AC-6000

5 inch Color TFT Touch Screen

Intuitive UI , simplifies operation
User definable screen layout and background.
AC-6000
AC-6000

USB Memory

Transfers configuration settings, images, firmware
and transaction logs using a USB Memory Stick.

supra usb 2.0 a-b-3

Proximity Sensor

Recognizes the approach of a
user and automatically turns on the
LCD and keypad.
Reduces power consumption.
AC-6000

Specification

Detail Specification AC-6000

CPU RISC 806MHz, 32bit CPU Memory 256MB RAM + 256MB SD Memory
LCD 5 inch color TFT Touch Screen Max Users 100,000
Communication TCP/IP, Wiegand In/Out,
RS485, RS232, Wi-Fi (optional)
Log Capacity 500,000
Dimension 198 X 120 X 40 mm Certificates KC, CE, FCC, RoHS
CPU RISC 806MHz, 32bit CPU
Memory 256MB RAM + 256MB SD Memory
LCD 5 inch color TFT Touch Screen
Max Users 100,000
Communication TCP/IP, Wiegand In/Out, RS485, RS232, Wi-Fi (optional)
Log Capacity 500,000
Dimension 198 X 120 X 40 mm
Certificates KC, CE, FCC, RoHS

Configuration

See what’s included in the AC-6000

AC-6000

LOGO

 

AC-4000

AC-4000

Affordable Fingerprint Recognition
Access Controller

Brochure Download

User Manual Download 

Door Phone Interface

AC-4000
AC-4000

Proximity Sensor

Recognizes the approach of a user
and automatically turns on the LCD and keypad.
Reduces power consumption.

Specification

Detail Specification AC-4000

CPU RISC 32bit CPU Memory 4MB Flash + 8MB SD RAM
LCD 128×64 Graphic Display LCD Max Users 22,000
Communication TCP/IP, Wiegand In/Out, RS485, RS232 Log Capacity 55,000
Dimension 181 X 109 X 47 mm Certificates KC, CE, FCC, RoHS

 

CPU RISC 32bit CPU
Memory 4MB Flash + 8MB SD RAM
LCD 128×64 Graphic Display LCD
Max Users 22,000
Communication TCP/IP, Wiegand In/Out, RS485, RS232
Log Capacity 55,000
Dimension 181 X 109 X 47 mm
Certificates KC, CE, FCC, RoHS

Configuration

See what’s included in the AC-4000

AC-4000

LOGO

 

AC-5000

AC-5000

Outdoor IP65 Fingerprint Terminal
An evolution in fingerprint terminal technology,
incorporating state of the art design, elegant looks and
a robust IP65 rated housing.

2.8 inch Color Screen

Intuitive UI , simplifies operation
User Customizable LCD Background
AC-5000
AC-5000

Dustproof / Waterproof

IP65 level of Dustproof / Waterproof structure

PoE (Power over Ethernet)

Easy installation with terminal connectors
AC-5000

Specification

Detail Specification AC-5000

CPU RISC 400MHz, 32bit CPU Memory 32MB RAM + 32MB SD Memory
LCD 2.8 inch color LCD Max Users 20,000
Communication TCP/IP, Wiegand In/Out, RS485, RS232 Log Capacity 61,000
Dimension 88 X 175 X 43.5 mm Certificates KC, CE, FCC, RoHS
CPU RISC 400MHz, 32bit CPU
Memory 32MB RAM + 32MB SD Memory
LCD 2.8 inch color LCD
Max Users 20,000
Communication TCP/IP, Wiegand In/Out, RS485, RS232
Log Capacity 61,000
Dimension 88 X 175 X 43.5 mm
Certificates KC, CE, FCC, RoHS

Configuration

See what’s included in the AC-5000

AC-5000

LOGO

 

 

AC-F100

AC-F100

Smart Access Device

ACF100 is an evolution in Biometric Access Control technology
A new standard in aesthetic and robust design is achieved without
compromising technical functionality.

Brochure Download

User Manual Download

AC-F100

Smartphone
Application (i-UNIS)

Access control and time management application
by Android, iOS
Reduces the installation time and cost with Wi-Fi
AC-F100
AC-F100
AC-F100

Dustproof / Waterproof

IP65 level of Dustproof / Waterproof structure

1.3 Mega Pixel Digital Camara

Records a digital image of each user
at the time of the transaction
AC-F100

Specification

Detail Specification AC-F100

CPU RISC 32bit 400MHz CPU Memory 256MB RAM + 256MB SD Memory
Key Button F1~F4 Touch Type Max Users 1,000
Communication Wi-Fi, Wiegand Out, RS485 Log Capacity 1,000,000(text) / 10,000(image)
Dimension 63 X 138 X 41.3 mm Certificates KC, CE
CPU RISC 32bit 400MHz CPU
Memory 256MB RAM + 256MB SD Memory
Key Button F1~F4 Touch Type
Max Users 1,000
Communication Wi-Fi, Wiegand Out, RS485
Log Capacity 1,000,000(text) / 10,000(image)
Dimension 63 X 138 X 41.3 mm
Certificates KC, CE

Configuration

See what’s included in the AC-F100

AC-F100

LOGO

 

 

VTerminal

VTerminal

Virtual Clocking Terminal Solution

Brochure Download

User Manual Download 

2 Portable Terminal
No hassle for user to install anything.
Mobile devices work as portable terminals.
3GPS Transaction
Real-time GPS location data including a captured image sync with UNIS server installed at HQ or anywhere using 3G or Wi-Fi.
4 Convenient Installation
No network connection required for T&A service.
5 Time & Attendance for field workers
Real-time T&A log monitoring available. Lookup authentication log history by period, shown as image captures.

System Architecture

Network Service

VTerminal

Cloud Service

VTerminal

Application UI

 

LOGOAC-2200

AC-2200

Bluetooth-enabled
Smart Fingerprint Terminal

Brochure Download

User Manual Download 

Dustproof / Waterproof

IP65 level of Dustproof / Waterproof structure
AC-2200
AC-2200

1.77 inch Color Screen

Intuitive UI , simplifies operation

Digital Camera

Records a digital image of each user at
the time of the transaction. (640 x 480 pixel)
AC-2200
AC-2200

Smartphone Application
(UNIS-B plus, imkey)

Access control &
mobile key application by Android, iOS

Specification

Detail Specification AC-2200

CPU ARM9, 400MHz CPU Memory 32MB NOR+128MB NAND Flash, 64MB DDR RAM
LCD 1.77 inch Color LCD Max Users 20,000
Communication Bluetooth, TCP/IP, Wiegand In/Out, RS485, RS232, GPRS (Optional) Log Capacity 100,000
Dimension 58 X 191 X 62 mm Certificates KC, CE, FCC, RoHS
CPU ARM9, 400MHz CPU
Memory 32MB NOR+128MB NAND Flash, 64MB DDR RAM
LCD 1.77 inch Color LCD
Max Users 20,000
Communication Bluetooth, TCP/IP, Wiegand In/Out, RS485, RS232, GPRS (Optional)
Log Capacity 100,000
Dimension 58 X 191 X 62 mm
Certificates KC, CE, FCC, RoHS

Configuration

See what’s included in the AC-2200

AC-2200

LOGO

 

AC-7000

AC-7000

High performance
Face&Fingerprint Recognition Terminal

AC-7000 is the latest access controller with fake finger detection
and a tilt camera which automatically detects a face within 3m.
Its 5″ touch LCD and familiar UI such as Android smartphone
Apps greatly enhance user convenience.
AC-7000

Auto height angle adjustment

A tilt camera offers auto face detection.
No need to lower posture or bend the knees
AC-7000

Face detection in the dark

IR LED Camera offers user convenience as it detects
face even in the dark without any trouble.
AC-7000
AC-7000

Simultaneous double
authentication by Dual CPU

Dual CPU provides fast simultaneous
face & fingerprint double authentication

VoIP support

VoIP with improved sound quality is provided.
AC-7000

Specification

Detail Specification AC-7000

CPU 1 GHz Quad Core (Dual) Memory 4GB NAND + 8GB microSD
LCD 5″ Color Touch LCD Max Users Finger 250,000 (1:1)/ 25,000 (1:N) | Face 10,000 (1:1)/2,000 (1:N)
Communication TCP/IP, Wiegand, RS485, RS232, Wi-Fi (Opional) Log Capacity 100,000,000 (text)/ 20,000 (image)
Dimension 149.5 x 208.5 x 46mm Certificates KC, CE, FCC
CPU 1 GHz Quad Core (Dual)
Memory 4GB NAND + 8GB microSD
LCD 5” Color Touch LCD
Max Users Finger 250,000 (1:1)/ 25,000 (1:N) | Face 10,000 (1:1)/2,000 (1:N)
Communication TCP/IP, Wiegand, RS485, RS232, Wi-Fi (Opional)
Log Capacity 100,000,000 (text)/ 20,000 (image)
Dimension 149.5 x 208.5 x 46mm
Certificates KC, CE, FCC

Configuration

See what’s included in the AC-7000

AC-7000

ST680b

 

 

Soca

Proximity main reader can be connected to computer to provide online information inquiry/setting, door opening and closing, alarm activation and etc. It can be used as standalone operation.
During the operation of the proximity main system, historical data (recording entry & exit information) storage can be reached up to 6,000 batches. When it is being connected with computer, the capacity of recording of entry and exit information is unlimited which records detailed data of the cards.
Proximity main system’s maximum capacity for valid cards is 9,000 cards. Each card self set individual password and time zone for entry and exit.
The entry and exit control area of proximity main system includes card number, password, time zone, special holidays, status control, and anti-passback.
When the reader has detected that the system has been damaged or the door has been opened illegally or the door did not close over a specific time limit, then alarm will be activated.
System provides 48 sets of time zone for user to set. Each time zone has five time districts.
The system has self hardware testing function when the equipment is power on.
Anti-duress function available and user is able to enter specific password to send help signal.
Door open methods: proximity, proximity and password, push button, door open by the computer’s command, special system password.
When sudden power cut occurred, internal battery would operate and therefore information in the internal memory will not be lost and system timer can be operated as normal.
One proximity reader can be added to the sub-reader for controlling of entry and exit.
Single proximity or card number entry.
Simple attendance function. The day’s first and last data as attendance data (available in text file when exporting).
External sub-reader available to connect.
Maximum proximity distance: 15cm (125KHz), 5cm (13.56MHz) (depending on types of card).
Power consumption: 180mA (standby); 210mA (operation)
Frequency: 125KHz or 13.56MHz.
Operation temperature: 0~60℃; Humidity: 85%Rh max.
Dimensions: 160(L)×100(W)×30(H) (mm)
Weight:450g
Certification: CE

ST-660-Dimension-e

Product data sheet and certificatesBoard 10 copy

HoringLih has designed high quality safety and protection products for a wide range of fire alarm systems including detectors, control panels, fire alarm components and many more. The addition of our state-of-the-art manufacturing facility enables us to maintain quality assurance as we continue to expand throughout the whole world. With our distributors serving over 50 countries, we have established a world-wide distribution network.

HoringLih has been in the Fire Alarm market for 31 years and we have built a fine reputation based on our customers’ feedback. We continually bring new products into the market because HoringLih knows what customers need.

HoringLih has a long-term devotion to the fire alarm business with only one purpose – “We are concerned about people’s life.”

 

 

Soca

Multiple waterproof design. Built-in doorbell push button. Available to install indoors or outdoors.
LED display screen. Display time when it is stand-by. Display card number when proximity. Show setting state when it is stand-alone setting.
Networking with both unit and computer for instant data enquiry/setting, open/close door, alarm activation and etc. Access control available for stand-alone operation.
Maximum of 9,000 records of data when it is stand-alone. Unlimited records of data when it is networking. Detailed information of each card at the time is recorded.
Maximum of 4,500 cards for proximity unit. Each card is able to set its personal password and valid access time frames.
The Range of access control by the unit includes card number, password, time frame, holidays, error control, and etc.
The range of detection by the unit includes unit is being tampered, unauthorized door open, door does not close (exceeding time), anti duress, anti-theft detection, push button door open.
48 time frames available to set. Each time frame has 5 time zones.
The unit has self-testing function.
Single card proximity entry, single card number entry, or batch entry and cards are able to issue in advance.
Door open methods: proximity, proximity and password, push button, door open by the computer’s command, special system password.
Anti-duress function available and user is able to enter specific password to send help signal.
External sub-reader available to connect.
One proximity reader can be added to the sub-reader for controlling of entry and exit.
Simple attendance function. The day’s first and last data as attendance data (available in text file when exporting).
Maximum proximity distance: 10cm(125KHz), 5cm(13.56MHz) (depending on types of card)
Power supply: 12VDC ±10%,Frequency:125KHz or 13.56MHz
Operation temperature: 0~60℃ ; Humidity: 85%Rh max
Dimensions: 140LX60WX30H (mm)
Weight:265g
Certification: CE

Waterproof
      * Please mount the unit on a smooth surface.
The waterproof rubber cushion on the back panel is placed on the wall firmly to achieve complete
front panel waterproof effect.
Dimensions

Soca

 

 

Slim type and require only 6cm to install.
External RELAY module to enhance security.
Multiple water proof design to be able to install outdoors. Built-in doorbell push button.
8 sets of door open password available to set.
Anti-duress function available and user is able to enter specific password to send help signal.
Alarm will activate when unauthorized entry or access occurred.
Single card proximity entry, single card number entry, or batch entry and cards are able to issue in advance.
Add new or delete specific card.
Anti-tamper function available and alarm will activate when the unit is moved or tampered with force.
Special memory to prevent loss of data when power cut occurred.
Door open time (01~98 sec). 99 sec. as normal setting for security setting or releasing. 00 sec. as instant trigger time.
Fireproof polycarbonate material for casing. White or dark gray available.
Both upper and lower cases are fixed with special screws. Use of special tool to disassemble.
Maximum capacity of 1000 cards (8-digit card number).
5 door open methods: Password entry, proximity entry, proximity and password entry, password or proximity entry, and special system password entry.
Power consumption: Stand-by 80mA; Operation 110mA
Maximum proximity distance: 10cm(125KHz), 5cm(13.56MHz) (depending on types of card)
Frequency: 125KHz or 13.56MHz. Power supply: 12VDC ±10%
Operation temperature: 0~60。C; Humidity: 85%Rh max.
Dimenisions:130(L) X 61(W) X 25(H) (mm)
Weight:235g
Certification: CE

Waterproof
Structure diagram
 Reader connector

 

Smartline

 

SmartLine


EN54-2;EN54-4 certified
EN12094-1 (CPD) certified 
Conventional control panels with 2 zones or 4 zones expandable to 36
The SmartLine conventional fire-detection control panel series offers a 2 zone non-expandable model (SmartLine020-2), a 4 zone model expandable to 20 zones (SmartLine020-4) and a 4 zone model expandable to 36 zones (SmartLine036). The extreme compactness, trouble-free installation, uncomplicated programming procedures and simple end-user operation make this highly competitive control panel ideal for all small and medium applications, especially those applications where fast installation and programming are among the most important aspects of the system. The numerous functions (timers, equational logic, etc.), extensive flexibility (automatic output balancing, multifunction inputs, customizable outputs, gas function integration, etc.), and innovative connectivity capabilities (RS485 BUS for power supply stations, Internet connection, etc.), provide the tranquillity of knowing for sure that this powerful tool is capable of satisfying every need of every type of installation. SmartLine control panels have supervised outputs (one on the motherboard and one on each added expansion) for the activation of audio-visual signalling devices, a customizable relay output, fault signaling outputs and two 24V outputs (one constant and one interruptible by installer-defined conditions). Additionally, each detection zone provides a terminal which can be configured as: open-collector output (activated by programmable conditions), supervised input, or Gas 4-20mA detector interface. System information is provided through the graphic display and LEDs on the control panel frontplate. The RS485 BUS supports 4 remote repeater panels (SmartLetUSee/LCD-Lite). These repeater panels replicate all the fire alarm system data and allow users to access and control the system in accordance with their authorized access level. The BUS also supports two power-supply stations which can be connected in such a way as to allow supervision of their functionality and activation/deactivation of their output power during predefined conditions. Programming the system from the control panel is straightforward and trouble-free thanks to the easy-to-follow instructions on the display. The system can also be programmed by means of the SmartLeague software application. This intuitive programming software greatly simplifies the programming procedure. The SmartLAN/485 board allows the control panel to connect to an Ethernet network for remote access via the Internet. Once the remote connection has been established, it is possible to modify the configuration parameters, upload/download programming data and/or manage the system by means of the supervisory software based on SmartLook graphic maps.

TCW240B – Data acquisition module

Short Description

TCW240B is a data acquisition module, designed to work in Ethernet based networks. It includes 4 digital inputs, 4 analog inputs, 1-Wire interface for up to 8 Teracom 1-Wire sensors like temperature, humidity, CO2, current, 4/20mA, galvanic isolated analog voltage etc. It also has 4 relays with normally open and normally close contacts.

The relays can be activated either remotely (WEB, SNMP, HTTP etc.) or locally – from status of monitored parameter (1-Wire sensor, analog voltage and dry contact). Only one parameter can control the relay at the same time, but for every parameter can be sent e-mail/SNMP trap for alert conditions.

Embedded real time clock gives a possibility to arrange scheduled task in time. The tasks can be either single or with weekly repetition.

Features : – 

  • Password protected web based configuration and control;
  • 4 digital inputs with ” dry contact” and “logic level” modes;
  • 4 analog inputs with 0 to 60VDC range;
  • Multiplier and offset for analog inputs;
  • 4 relays with NO and NC contacts;
  • SNMP v.2 support;
  • SNMP traps and/or e-mail sending for alert conditions;
  • 2K SSL support;
  • XML and HTTP API commands;
  • NTP protocol support;
  • Push mode for client-server systems;
  • Real time clock for scheduler control;
  • Remote firmware update.

Typical Application : –

The big number of digital and analog inputs, supported 1-Wire sensors and relay outputs makes TCW240B-CM good choice for various application such as:

 

  • Data acquisition module systems;
  • Home and office alarm systems;
  • Home automation;
  • Mushroom and winery environmental monitoring and control;
  • Environmental monitoring and control of server rooms;
  • Heaters or coolers control;
  • Scheduled control of processes;
  • Industrial process automation.

 

TCG120 – GSM/GPRS controller

Short Description

TCG120 is a micro-controller based device for GSM-GPRS temperature monitoring and control over mobile networks. It has 2 digital inputs, 2 analog inputs, 1-Wire interface for up to 4 Teracom humidity and temperature sensors. Its 2 relays has normally open and normally close contacts.

The relays can be activated either remotely (via SMS or HTTP API command) or locally – from status of monitored parameter. Only one parameter can manage the relay at the same time, but for every parameter can be sent e-mail or SMS for alert conditions.

The controller can be used as standalone device or as a part of data acquisition (SCADA) systems. TCG120 may periodically send data to a remote server, which makes it suitable for use in client-server systems for GSM-GPRS temperature monitoring and control.

Features :- 

  • Quad-bands GSM connectivity;
  • Setup via USB (Windows setup program) or SMS;
  • 2 digital inputs with ” dry contact” and “logic level” modes;
  • 2 analog input with 0 to 60VDC range;
  • 2 relay output with NO and NC contacts;
  • Long 1-Wire support for up to 4 Teracom TSTxxx (temperature) and TSHxxx (temperature&humidity) sensors;
  • SMS alarm alerts (up to 5 numbers);
  • Email alarm alerts (up to 5 email recipients), SMTP with SSL support;
  • Single call control – the relays can be controlled with a single call from up to 100 numbers;
  • Push mode – XML data is sent via HTTP post method to remote server;
  • HTTP API commands;
  • Firmware update over USB or GPRS.

 

Typical Applications :- 

TCG120 is an universal device and can be used in various aplications such as:

Remote environmental monitoring and control for homes, offices, server rooms etc;

  • Temperature and humidity control;
  • Remote control of electric devices;
  • Home and office alarm systems;
  • Industrial process automation;
  • Control and management of large networks.

 

Carbon Monoxide is a colorless, odorless, tasteless and highly toxic gas. It will reduce the oxygen in body’s hemoglobin and cause damage to the brain. Our QA23 is equipped with a precise and low power-consumption sensor. With high efficiency microprocessor-based analysis, it can be triggered under different carbon monoxide concentrations.


Characteristics

  • High luminous dual LEDs to indicate different status.
  • Green LED to confirm the unit is under normal operation.
  • Each visible and audible warning has 4 modes to easily identify current status.
  • Test button for alarm simulation.
  • Dual power input: 12VDC and 24VDC operation in the same unit. No adjustment is required.
  • Optional 110VAC or 220VAC adaptor is available.


Specifications

Model
QA23
Power Source
24V DC
12V DC
Standby Current
1 ~ 25 mA
1 ~ 20 mA
Alarm Current
10 ~ 85mA
10 ~ 55mA
Sensitivity
50 ppm : 60 ~ 90 min
100 ppm: 10~ 40 min
300 ppm: within 3 min
Warm-up Period
About 3 minutes
Alarm Sound
70dB/3M and above
Indicator
Standby: Red LED flashes every 60 sec
Early warning: Red LED flashes every 3 sec and beeps every 3 sec
Alarm: Red LED flashes and beeps every sec
Fault: Red LED flashes and beeps every 10 sec
Ambient Temperature
-10oC ~ +55oC
Dimensions
102 mm (Dia.) x 40.5 mm(H)
Weight
About 150g

 

Approval

 


Characteristics

  • Removable front board for easy maintenance.
  • Easy-to-clean front board is able to avoid dirt attached.
  • High luminance and long life span LED.
  • Build-in 24V power and battery charger.
  • Compatible with most brands of conventional detectors.
  • Independent visual & audible indication for zone open/short fault.
  • Independent visual & audible indication for AC power & battery fault.
  • Visual & audible indication for sounder short circuit fault.
  • Buzzer silence with 3-mode operation feature.
  • Accurate supervision circuit for battery.
  • Day/Night Mode Selection. (Model. QP212, QP412)
  • System will back to normal automatically after alarm status is released. (Model. QP212, QP412)
  • Ground fault detection feature. (Model. QP212, QP412)
  • Fault Output (NO. NC. COM), Alarm Output (NO. NC. COM.), Zone Output. (Model. QP212, QP412)
  • 24V DC power output for external load (Model. QP412)
  • l Zone EOL resistor can be set from panel board (Model. QP412)

 

Specifications

Model
QP412
Power
220V AC, 50/60Hz *Others also available
Battery Capacity
24V / 1.2Ah
Max. Output Current
2.0A
# of heat detectors connected
No limit *Except electronic-type
# of smoke detectors connected
20/zone *Horing Lih manufactured
End of Line Resistor
4.7 kΩ
Material
1.2mm steel plate
Dimensions (H x W x D)
203 x 273 x 72 mm
Approval

 

Characteristics

  • QA12 could up to 80 zones.
  • Alarm verification up to 7 seconds for real fire confirmation and avoid false alarm from environment interference.
  • Zone test mode to perform alarm and fault functional test.
  • Each zone has a separate disable function.
  • Fault indications for wire disconnection, unstable AC power, battery short circuit or disconnection and internal PCB unplug.

Specifications

Model
QA12
Power Source
220V AC, 50/60Hz others also available
Battery Capacity
24V / 4Ah
# of heat detector connected
No limit *Except electronic-type
# of smoke detector connected
30/zone *Horing Lih manufactured
End of Line Resistor
10KΩ *One per zone
Material
1.2mm steel plate
Color
Pearl gray *Others also available
Dimensions
10 zones–450 mm (H) x 330 mm(W) x 130 mm(D)
20 zones–550 mm (H) x 330 mm(W) x 130 mm(D)
30 zones–680 mm (H) x 380 mm(W) x 150 mm(D)
40/50 zones–950 mm (H) x 420 mm(W) x 150 mm(D)
60~80 zones–1300 mm (H) x 420 mm(W) x 170 mm(D)
Approval

 

 

 

4 Zone
8 Zone
32 Zone

Characteristics

  • Model range from 1 to 32 zones.
  • AC power supply has EMI (Electromagnetic Interference).
  • Each zone has a separate disable function.
  • Double sets of sounder contacts.
  • Automatic telephone dialer feature.
  • Long-term or temporary silencing feature.
  • Protection against voltage spikes up to 2.5KV.
  • Microprocessor-base design.
  • Sounder short circuit or disconnection detection.
  • Fire Alarm NO, NC, COM and Fault NO, NC, COM output contact points.
  • Fire Relay Output contacts and Fault Relay Output contacts.
  • Switch membrane provides longer service and is waterproof, dust resistant and easy to clean.

 

Specifications

32 Zone
8 Zone
4 Zone
Model
AH-03312-32L
AH-03312-8L
AH-03312-4L
Power
220V AC/50Hz *Others also available
Battery Capacity
24V/12Ah
24V/7Ah
24V/4Ah
Max. Output Current
2A @24V DC
# of heat detectors connected
No limit *Except electronic-type
# of smoke detectors connected
30/zone *Horing Lih manufactured
Max. No. of Bells @25mA
40 per sounder circuit
End of Line Resistor
4.7kΩ *One per zone
Material
1.2mm steel plate
Dimensions
550mm(H)
400mm(W)
150mm(D)
370mm(H)
340mm(W)
135mm(D)
320mm(H)
250mm(W)
100mm(D)
Optional Features LCD display (2×20) with simple function keypad N/A
Approval

 

 

Characteristics

  • Panel and manual pull station count-down simultaneously.
  • Discharge delay timer setting (20 ~ 999 seconds).
  • Cross-zone detection confirmation makes better stability.
  • Built-in phone jacks on both panel and manual pull station.
  • Expandable to 5 cross-zone detection sections.
  • Each section has manual/auto operation mode.
  • Wiring trouble inspection.
  • Through dipswitch to select the supervision on feed-back signal of agent discharge.
  • All 24V output contacts are protected by fuse.

Specifications

Model
QSP-120
Power 220V AC 50/60Hz *Others also available
Battery Capacity 1 cross-zone: 24V DC 1.2Ah 5 cross-zone: 24V DC 4Ah
Zone Voltage 24V DC
EOL Resistance 4.7kΩ
Detection Type Cross-zone detection
# of heat detectors connected No limit *Except electronic-type
# of smoke detectors connected 25/zone *Horing Lih manufactured
Dimensions 1 cross-zone: 350(H) x 400(W) x 130(D) 5 cross-zone: 550(H) x 400(W) x 130(D)
Color Ivory
Approval

Characteristics

  • This compact and esthetic unit is ideally suited for a variety of agent-releasing applications such as FM-200, CO2, Dry & Wet Chemical.
  • Large unit accommodating more zones are also available.
  • Agent can be releasing automatically or manually.
  • System enables highly reliable monitoring and suppression control.
  • Audible and visible indication when system has fault condition.
  • Digital release countdown.

Specifications

Model
AH-02120
Power 220V AC/50Hz *Others also available
Battery Capacity 24V DC 4Ah
Zone Voltage 24V DC
EOL Resistance 10kΩ
Detection Type Cross-zone detection
# of heat detectors connected No limit *Except electronic-type
# of smoke detectors connected 30/zone *Horing Lih manufactured
Dimensions 420mm(H) x 380mm(W) x 130mm(D)
Color Ivory
Approval

AH-03233 Releasing Indicator

Features
The displayed contents can be made according to customer’s requirement.

Specifications

Model
AH-03233
Supply Voltage 24V DC 670mA (bulb) 310mA (LED)
Light Source 1W bulb x 18 or ?Ø5 LED RED x 28
Display Type Non-flash
Material 0.8mm stainless steel
Color Red
Dimensions 155mm(H) x 405mm(W) x 80mm(D)


AH-03232 Manual Pull Station

Features

  •  Emergency START/STOP switch, AUTO/MANUAL key switch.
  • POWER LED, RELEASING LED, START LED, STOP LED, AUTO LED, and MANUAL LED.
  • Digital Release Countdown.

Specifications

Model
AH-03232
Supply Voltage 24V DC
Material 1.2mm stainless steel
Color Red
Dimensions 160mm(H) x 165mm(W) x 50mm(D)

 

Approval

 

Characteristics

  • This detector operates on the temperature differential sensing principle, with a UL approved sensor making mechanical contact. It is made of high quality material, providing excellent contact despite any environmental interference.
  • This detector is suitable for locations with high temperatures differentials, such as places (kitchen, restaurant and boiler house) where there is constant use of heat.
  • This detector has passed strict quality control and repetitive testing; hence its quality is durable and highly reliable.
  • Through its professional design, the heat collector can accelerate its response rate after being heated, and has a protective device to avoid accidental response caused by distortion, bumping and dropping in order to increase the reliable product.
  • The unit is completely sealed; its function is not affected by humidity, dust or insects.


Specifications

Model
AH-9920
Type
2-wire
3-wire
4-wire
Alarm Contact
N/A
N/A
0.8A @30V DC
0.4A @125V AC
Thermal Setting
70oC or other selections
Voltage Range
12 ~ 30V DC
Alarm Current
@24V DC 470Ω
40mA 40mA 30mA
Alarm Temperature Comply to EN54
Ambient Temperature -10oC ~ +55oC
Material Fire-proof plastic
Dimensions 111mm(Dia.) x 47mm(H)
Weight About 100g
Color White

 

Effective alert area

Construction/Height
Under 4M
4M ~ 8M
Fire-proof Building
60 M2
30 M2
Ordinary Building
30 M2
15 M2

 

Approval

 


Description

The detector has wide-angle sensitivity that can reliably and quickly detect weak ultraviolet radiations emitted by flame. It will not react to room illuminations, infrared or other light sources unrelated to real fire.

Installation Instructions

  • Install at obstruction-free places.
  • Avoid installing near mercury lamps, halogen lamps and sterilization lamps.
  • Avoid installing within sensitive range of welding sparks and radiation.

Applications

  • Premises with higher ceilings: theater, gym, storage, gallery or warehouse, etc.
  • Places where fires happen easily: places storing with combustible goods, gas stations, factory working places, machine rooms, etc.
  • Ventilate places: open markets, station platforms, hotel lobbies, department stores, etc. (places that smoke and heat can not gather during early period of fire)
  • Others: tunnels, computer rooms, etc.


Specifications

Model
AH-0014
Type
2-wire
3-wire
4-wire
Alarm Contact
N/A
N/A
0.8A @30V DC
0.4A @125V AC
Voltage Range
12 ~ 30V DC
Alarm Current
@24V DC 470Ω
35mA
35mA
30mA
Standby Current
45μA
Sensor Type
Ultraviolet
Sensitivity Angle
120°
Sensitivity Range
It can detect flame of 15mm at distance of 3m
Ambient Temperature
-10℃ ~ +55℃
Material
Fire-proof plastic
Dimensions
111mm(Dia.) x 47mm(H)
Weight
About 170g
Color
White
Approval

 

 

 


Characteristics

  • The QA31 features advanced photoelectric technology for precise detection. When smoke is detected or the manual test button is pressed, the buzzer sounds and LED flash.
  • Low-Battery Warning: Unit beeps and LED flash intermittently to indicate battery needs replacing.
  • Simple test method: Press test button to hear the alarm sound and confirm the unit is in normal condition.
  • Easy installation: Install directly to proper location without any wiring.
  • It is equipped with 9VDC battery, and optional 110VAC or 220VAC power plug is available.
  • Optional relay output : COM. NO. NC.
  • Optional series connection wiring can co-activate up to 15 detectors.

 

Specifications

Model
QA31
Power
9V battery
Sensitivity Setting
Comply to EN14604
Indicator
Standby: flash every 40 seconds
Alarm: flash and beep continuously
Battery abnormal: beeps and flash intermittently
Sound
90dB / M and above
Ambient Temperature
-10oC ~ +55oC
Material
Fire-proof plastic
Dimensions
105mm(Dia.) x 40mm(H)
Weight
About 150g
Color
White
Optional Function
Type 1 : 9V battery
Type 2 : includes signal transfer COM. N.O. N.C.
Type 3 : build-in 110VAC or 220VAC plug
Type 4 : Type 2 + Type 3

 

Effective alert area

Building Height
Area Covered
Under 4M
150 M2
4 ~ 20M

75 M2

 

Approval

 


Characteristics

  • The AH-0822 features advanced technology, high accurate detection, low power-consumption and fast reaction time. It can detect natural gas and propane gas. Built-in buzzer and LED indicator alert by sounding and flashing.
  • Sounding and flashing in alarm status; the green LED is lit during monitoring and the red LED flashes in alarm status.
  • Dual power input: 12VDC and 24VDC operation in the same unit. No adjustment is required.
  • Optional 110VAC or 220VAC adaptor is available.

 

Specifications

Model
AH-0822
Approval
UL
CE
Power Source
24V DC
12V DC
24V DC
12V DC
Standby Current
25~30mA
40~45mA
35~40mA
65~70mA
Alarm Current
40~70mA
50~75mA
75~90mA
90~105mA
Warm-up Period
5 ~ 8 minutes
About 35 seconds
Sensitivity
0.021 ~ 0.300% (Propane)
0.050 ~ 0.714% (Methane)
0.05 ~ 0.30%
Alarm Sound
85dB/3M and above
90dB/M and above
Detection Type
Natural Gas & Propane Gas
Ambient Temperature
-10oC ~ +55oC
Dimensions
102 mm (Dia.) x 40.5 mm(H)
Weight
About 130g

 

Approval
 

AH-413
AH-01313
UL Approval

Features
This unit is designed to ensure that alarm signal can be actually transmitted to all locations. Especially for a closed room, any fire inside can be indicate outside.

Characteristics

  • Outstanding look from the design of art
  • Low current consumption
  • High intensity LED for quick identification
  • Larger indicating lamp. (Model. AH-413)
  • Applicable for 12VDC and 24VDC (Model. AH-413)
  • Flash light is available for optional feature (Model. AH-413)

Specifications

Model
AH-413
AH-01313
Power Source
12/24V DC
24V DC
Alarm Current @24V DC
15mA
12mA
Standby Current
N/A
Ambient Temperature
-10oC ~ +55 oC
Material
Fire-proof plastic
Color
White surface/ Red LED
Dimensions (mm)
85(H)x85(W)x23(D)
70(H)x70(W)x15(D)
Weight
About 28g
About 32g

 

Approval

Characteristics

  1. For testing heat and smoke detectors.
  2. Extension pole is very flexible. It has five sections and can expand from 1.44m to 5m.

AH-03128

  1. Removal device is designed for AH-031 series detector. (AH-0311, AH-0315 and AH-0316)
  2. The extension pole on the test vessel allows the user to easily reach the detector.
  3. The enclosed gas torch its temperature can be adjusted.
  4. The smoke detector tester can spray about 500 times.

AH-07128

  1. Use with model nos. 8011, AH-0715 and 8016.

AH-03127-BS AH-03127-S


General

This electronic sounder is designed for use with fire alarm systems, security systems and industrial signaling systems. Combined sounder and beacon provides an audio-visual warning which is suitable for places where high sound output and visual indication is required.


Characteristics

  • 32 signal tones selectable by Dip switch.
  • High sound output with low current consumption.
  • High efficiency lens for maximum light output.
  • Volume Control as standard.
  • Two sets of IN and OUT terminals, easy for installation


Specifications

Model
AH-03127-S
AH-03127-BS
Voltage Range
24V DC
Current Consumption
24V DC (tone 3)
14.5mA
Sound Output 24V DC
dB (A) at 1 meter
Max. 114
Volume Control
0 to -20dB adjustment
Ingress Protection
IP44
Ambient Temperature
-25℃ ~ +80℃
Material
ABS plastic
Dimensions
92.5mm(Dia.) x 94mm(H)
92.5mm(Dia.) x 110mm(H)
Weight
254g
278g

 

Order information

AH-03127-S
Electronic Sounder
AH-03127-BS
Electronic Sounder and Beacon
Approval
 Features

  • High efficiency low current consumption on 24VDC motorized bells.
  • Terminals will accept 2.5mm cables.
  • Simple installation via multi-fixing base plate for all types of location.
  • Fitted with two series diodes for fault monitoring.
  • Option of customized discs printed with company name and logo.
  • 12VDC bells are also available.

Specifications

Model AH-0218
Dimensions Ø6″ (152mm) x 56mm(H)
Voltage 24V DC
Current 25mA
Sound Output 93dB @1M
Movement Motor, Pinion and striker
Movement Features DC Motor, acetal gear wheel, steel striker
Gong Steel, secured with phillips screw
Base Plate Molded black polycarbonate
Weight
About 850g
Approval

 

AH-9717 with base AH-9717


Features

  • Emergency press alarm, immediately activates fire alarm signal.
  • Indicator light above fire alarm push-button confirms the alarm signal transfer.
  • There are a phone jack and reset button behind the cover cap.
  • Type I is simultaneous dual loop, Type II is simultaneous dual signal transfer (refer to diagram below)
  • Optional base is available.

Specifications

Model AH-9717
Operating Power 24V DC 30mA
Operating Contact Max. 30V DC 500mA
Sub-function Phone jack, confirmation LED, reset button.
Material Fire-proof plastic
Dimensions 140mm(Dia.) x 45mm(H)
Weight About 160g


EN approval
CE approval


Features

  • Available in flush or surface mounted models.
  • Plastic film on glass.
  • Test key inserted from bottom.
  • Suitable for the majority of conventional fire alarm system.
  • Clear protection cover is also available (optional).
  • Choice of red, yellow, blue or green finish also available for custom-made.

Specifications

Model AH-0217
Operating Contact 6A 125/250VAC
Resistance 30mΩ
Ambient Temperature -25℃ ~ +85℃
Dimensions 88mm(H) x 88mm(W) x 52mm(D)
Weight About 165g

 

Approval
Features

  • Red LED with current limiting resistor.
  • Three different resistance selectable (270, 470, 680 ohm).
  • Choice of red, yellow, blue or green finish also available for custom-made.
  • Clear protection cover is also available (optional).

Specifications

Model AH-0817
Operating Contact 6A 125/250VAC
Resistance 30mΩ
Ambient Temperature -25℃ ~ +85℃
Dimensions (mm) 87.5 (H) x 87.5 (W) x 54 (D)
Weight About 145g
Approval

 


Characteristics

  • Special chamber design has greatly decreased dust levels and improved detection accuracy.
  • Dual LEDs for 360-degree visibility.
  • Advanced technology enables this detector to increase its precision in fire detection, improve signals to avoid noise interference and thus reduce unwanted false alarm.
  • Low current consumption that allows more detectors to be used with each control panel.
  • Dual contacts on the base which enhance the connecting stability between sensor and base.
  • All bases are fitted with a shorting spring to permit maintenance without disconnecting when removing the detector head.

Multi-purpose Resettable Type

This unit has designed for relay output feature with optional individual power source and it has been used widely in the current market. This resettable detector is not only use as a fire alarm system but will also supervise input power via an optional relay output for power breakdown or wire break. Fault relay contact will open when power breakdown occur and fire alarm signal will transmitted to connected system or computer terminal when detector is activated. When the alarm signal is absent the detector will automatically return to standby status. Optional built-in buzzer can sound a warning at the first sign of fire. This detector is currently used quite often in security systems and is also promoted for use in communications, banking, shipping or the art business.


Specifications

Model
AH-0315-2
AH-0315-3
AH-0315-4
Voltage Range
12 ~ 30V DC
Standby Current
55μA
Alarm Current
@24V DC 470Ω
40mA
30mA
40mA
Sensitivity Setting
Comply to EN54
Thermal Setting
58℃
Response Grade
Comply to EN54, Grade 1
Ambient Temperature
-10℃ ~ +55℃
Material
Fire-proof plastic
Dimensions
102mm(Dia.) x58mm(H)
Weight
155g
157g
165g
Color
White

 

Order information

AH-0315-2
2-wire
AH-0315-3
3-wire with remote indicator output
AH-0315-4
4-wire with relay output

 

Specifications (Resettable)

Model
AH-0315-S
AH-0315-BS
AH-0315-BPS
Alarm Current
25mA
65mA
80mA
Standby Current
125μA
125μA
15mA
Voltage Range
12V DC
12V DC
12V DC
Weight
164g
166g
171g

 

Order Information (Resettable)

AH-0315-S
+ Relay Output
AH-0315-BS + Buzzer + Relay Output
AH-0315-BPS + Buzzer + Power off & Wire
Disconnection Warning + Relay Output

 

Effective alert area

Building Height
Area Covered
Under 4M
150 M2
4 ~ 20M
75 M2
Approval

 

 


Characteristics

  • Special chamber design has greatly decreased dust levels and improved detection accuracy.
  • Dual LEDs for 360-degree visibility.
  • Advanced technology enables this detector to increase its precision in fire detection, improve signals to avoid noise interference and thus reduce unwanted false alarm.
  • Low current consumption that allows more detectors to be used with each control panel.
  • Dual contacts on the base which enhance the connecting stability between sensor and base.
  • All bases are fitted with a shorting spring to permit maintenance without disconnecting when removing the detector head.

Multi-purpose Resettable Type

This unit has designed for relay output feature with optional individual power source and it has been used widely in the current market. This resettable detector is not only use as a fire alarm system but will also supervise input power via an optional relay output for power breakdown or wire break. Fault relay contact will open when power breakdown occur and fire alarm signal will transmitted to connected system or computer terminal when detector is activated. When the alarm signal is absent the detector will automatically return to standby status. Optional built-in buzzer can sound a warning at the first sign of fire. This detector is currently used quite often in security systems and is also promoted for use in communications, banking, shipping or the art business.


Specifications

Model
AH-0316-2
AH-0316-3
AH-0316-4
Voltage Range
12 ~ 30V DC
Standby Current
45μA
Alarm Current
@24V DC 470Ω
30mA
35mA
40mA
Thermal Setting
58℃
Response Grade
Comply to EN54, Grade 1
Ambient Temperature
-10℃ ~ +55℃
Material
Fire-proof plastic
Dimensions
102mm(Dia.) x58mm(H)
Weight
145g
147g
160g
Color
White

 

Order information

AH-0316-2
2-wire
AH-0316-3
3-wire with remote indicator output
AH-0316-4
4-wire with relay output

 

Specifications (Resettable)

Model
AH-0316-S
Alarm Current
35mA
Standby Current
30μA
Voltage Range
12V DC
Weight
157g

 

Order Information (Resettable)

AH-0316-S
+ Relay Output

 

Effective alert area

Construction/Height
Under 4M
4M ~ 8M
Fire-proof Building
90 M2
45 M2
Ordinary Building
50 M2
30 M2
Approval
 

Characteristics

  • Special chamber design has greatly decreased dust levels and improved detection accuracy.
  • Dual LEDs for 360-degree visibility.
  • Advanced technology enables this detector to increase its precision in fire detection, improve signals to avoid noise interference and thus reduce unwanted false alarm.
  • Low current consumption that allows more detectors to be used with each control panel.
  • Dual contacts on the base which enhance the connecting stability between sensor and base.
  • All bases are fitted with a shorting spring to permit maintenance without disconnecting when removing the detector head.

Multi-purpose Resettable Type

This unit has designed for relay output feature with optional individual power source and it has been used widely in the current market. This resettable detector is not only use as a fire alarm system but will also supervise input power via an optional relay output for power breakdown or wire break. Fault relay contact will open when power breakdown occur and fire alarm signal will transmitted to connected system or computer terminal when detector is activated. When the alarm signal is absent the detector will automatically return to standby status. Optional built-in buzzer can sound a warning at the first sign of fire. This detector is currently used quite often in security systems and is also promoted for use in communications, banking, shipping or the art business.


Specifications

Model
AH-0311-2
AH-0311-3
AH-0311-4
Voltage Range
12 ~ 30V DC
Standby Current
35μA
Alarm Current
@24V DC 470Ω
40mA
30mA
40mA
Sensitivity Setting
Comply to EN54
Ambient Temperature
-10°C ~ +55°C
Material
Fire-proof plastic
Dimensions
102mm(Dia.) x 49mm(H)
Weight
155g
157g
165g
Color
White

 

Order information

AH-0311-2
2-wire
AH-0311-3
3-wire with remote indicator output
AH-0311-4
4-wire with relay output

 

Specifications (Resettable)

Model
AH-0311-S
AH-0311-BS
AH-0311-BPS
Alarm Current
15mA
50mA
80mA
Standby Current
115µA
115µA
15mA
Voltage Range
12V DC
12V DC
12V DC
Weight
168g
170g
170g

 

Order Information (Resettable)

AH-0311-S
+ Relay Output
AH-0311-BS
+ Buzzer + Relay Output
AH-0311-BPS
+ Buzzer + Power off & Wire Disconnection Warning + Relay Output

 

Effective alert area

Building Height
Area Covered
Under 4M
150M2
4 ~ 20M
75M2
Approval